SENSOR RELIABILITY
Door and Window Contact Sensors: Alignment, Gaps and False Alerts
A contact sensor can look correctly installed yet report an opening when the frame flexes, the adhesive moves or the magnet sits just outside the model’s permitted gap. Diagnose the physical installation before bypassing the zone.
Installation checks
| Check | What to verify |
|---|---|
| Magnet alignment | Use the exact model’s alignment marks and maximum gap—not a visual guess |
| Moving parts | Mount the two halves so hinges, sliding tracks and loose frames cannot strike them |
| Surface | Clean, dry and stable; replace failing adhesive with an approved fixing |
| Metal frames | Check manufacturer guidance for spacers or an alternative sensor type |
| Battery and tamper | Confirm charge, cover closure, tamper status and hub supervision |
Test more than fully open and closed
- Open and close the door or window slowly while watching live status.
- Test the “almost closed” or latch-resting position that occupants actually use.
- Gently press and release the frame to reveal flex or excess gap.
- Repeat during colder, hotter or wetter conditions if the alert is seasonal.
- Check double doors, patio doors and sash windows at every moving meeting point.
- Run the alarm’s walk or zone test and confirm the correct sensor name appears.
Common alert patterns
At night
Temperature movement, a poorly latched door or battery voltage drop can expose a marginal gap.
During wind
Frame movement or an unlatched secondary leaf may briefly separate the magnet and sensor.
After redecorating
Paint, new seals, moved hardware or remounting can alter alignment by a few millimetres.
Related tools
Sensor product previews · Camera and sensor placement planner · Maintenance planner
Professional reference: ProtectUK alarm and CCTV guidance.
Last checked: 1 September 2026. Follow the sensor maker’s stated gap and mounting requirements.